Starten Sie Ihre Suche...


Durch die Nutzung unserer Webseite erklären Sie sich damit einverstanden, dass wir Cookies verwenden. Weitere Informationen

IsoMAG—An Automated System for the Immunomagnetic Isolation of Squamous Cell Carcinoma-Derived Circulating Tumor Cells

Diagnostics. Bd. 11. H. 11. MDPI AG 2021 S. 2040

Erscheinungsjahr: 2021

ISBN/ISSN: 2075-4418

Publikationstyp: Zeitschriftenaufsatz

Sprache: Englisch

Doi/URN: 10.3390/diagnostics11112040

Volltext über DOI/URN

GeprüftBibliothek

Inhaltszusammenfassung


Background: detailed information about circulating tumor cells (CTCs) as an indicator of therapy response and cancer metastasis is crucial not only for basic research but also for diagnostics and therapeutic approaches. Here, we showcase a newly developed IsoMAG IMS system with an optimized protocol for fully automated immunomagnetic enrichment of CTCs, also revealing rare CTC subpopulations. Methods: using different squamous cell carcinoma cell lines, we developed an isolation protocol ex...Background: detailed information about circulating tumor cells (CTCs) as an indicator of therapy response and cancer metastasis is crucial not only for basic research but also for diagnostics and therapeutic approaches. Here, we showcase a newly developed IsoMAG IMS system with an optimized protocol for fully automated immunomagnetic enrichment of CTCs, also revealing rare CTC subpopulations. Methods: using different squamous cell carcinoma cell lines, we developed an isolation protocol exploiting highly efficient EpCAM-targeting magnetic beads for automated CTC enrichment by the IsoMAG IMS system. By FACS analysis, we analyzed white blood contamination usually preventing further downstream analysis of enriched cells. Results: 1 µm magnetic beads with tosyl-activated hydrophobic surface properties were found to be optimal for automated CTC enrichment. More than 86.5% and 95% of spiked cancer cells were recovered from both cell culture media or human blood employing our developed protocol. In addition, contamination with white blood cells was minimized to about 1200 cells starting from 7.5 mL blood. Finally, we showed that the system is applicable for HNSCC patient samples and characterized isolated CTCs by immunostaining using a panel of tumor markers. Conclusion: Herein, we demonstrate that the IsoMAG system allows the detection and isolation of CTCs from HNSCC patient blood for disease monitoring in a fully-automated process with a significant leukocyte count reduction. Future developments seek to integrate the IsoMAG IMS system into an automated microfluidic-based isolation workflow to further facilitate single CTC detection also in clinical routine. Keywords: automation; circulating tumor cells; head and neck squamous cell carcinoma; immunomagnetic particle-based detection; liquid biopsy; metastasis. » weiterlesen» einklappen

Autoren


Gribko, Alena (Autor)
Stiefel, Janis (Autor)
Liebetanz, Lana (Autor)
Nagel, Sophie Madeleine (Autor)
Künzel, Julian (Autor)
Hagemann, Jan (Autor)
Stauber, Roland H. (Autor)
Freese, Christian (Autor)
Gül, Désirée (Autor)

Klassifikation


DDC Sachgruppe:
Naturwissenschaften

Verknüpfte Personen